12-Channel Holter Monitor

Full-disclosure, synchronized 12-lead ECG—advanced analytics for clinical-grade insights.

$519.00

12-Channel Holter Monitor

Full-disclosure, synchronized 12-lead ECG—advanced analytics for clinical-grade insights.

$519.00
24-Hour 12-Lead Monitoring
Advanced Software Analytics
Real-Time LCD Display
One-Click Reporting & Print

Compact & Easy to Carry

Weighing just 105g/3.7oz (excluding battery), this compact design is easy to carry and perfect for on-the-go, enabling quick and convenient ECG measurements anytime, anywhere.

Compact & Easy to Carry

Weighing just 105g/3.7oz (excluding battery), this compact design is easy to carry and perfect for on-the-go, enabling quick and convenient ECG measurements anytime, anywhere.

All-Day 12-Lead ECG, Ready for Clinical Review

Capture simultaneous 12-lead ECG with continuous 24-hour recording and PC-based analysis. Purpose-built for hospitals, clinics, and community screening, it pairs reliable signal acquisition with powerful post-processing to support confident clinical decisions.

All-Day 12-Lead ECG, Ready for Clinical Review

Capture simultaneous 12-lead ECG with continuous 24-hour recording and PC-based analysis. Purpose-built for hospitals, clinics, and community screening, it pairs reliable signal acquisition with powerful post-processing to support confident clinical decisions.

Built-In LCD Display

View live ECG waveforms, time, and battery status at a glance—no PC required for quick checks or bedside confirmation.

Anti-Interference & Anti-Shock

Anti-interference, anti-shock design maintains readable ECG waveforms during ambulation, transport, and daily activities—suppressing motion artifacts and dropouts for consistent data quality indoors and outdoors.

Anti-Interference & Anti-Shock

Anti-interference, anti-shock design maintains readable ECG waveforms during ambulation, transport, and daily activities—suppressing motion artifacts and dropouts for consistent data quality indoors and outdoors.

Fast Review, One-Click Reports

Review any time bucket in single or full-lead mode, then print comprehensive reports with one click. Case management keeps everything organized.

Fast Review, One-Click Reports

Review any time bucket in single or full-lead mode, then print comprehensive reports with one click. Case management keeps everything organized.

What’s Included in Your Holter Report

All essentials at a glance—from acquisition metrics to deep analytics—so clinicians can review, interpret, and report faster.

  • Study & patient overview

  • Arrhythmia summary (SVE & VE)

  • Hour-by-hour arrhythmia table

  • ST-segment analysis

  • Heart rate variability (HRV)

  • Histograms & Poincaré plots

  • Wake vs sleep comparisons

  • Trend pages

  • Representative ECG strips

  • “Danger/Diathesis” analysis panel

Atrial fibrillation analysis

Premature supraventricular contraction

Automated Arrhythmia Analysis

Leverage 10+ pre-set templates—atrial premature beats, ventricular premature beats, long intervals, atrial fibrillation, and more—plus user-defined patterns. The system classifies and flags pathologic waveforms to streamline review.

Supported Arrhythmia Events

  • V: Premature ventricular contraction (PVC)

(V: Premature ventricular contraction

V couplet: Ventricular couplet
V short run: Short ventricular run (non-sustained ventricular tachycardia)
V long run: Long ventricular run (sustained ventricular tachycardia)
V bigeminy: Ventricular bigeminy
V trigeminy: Ventricular trigeminy)

  • S: Premature supraventricular contraction (PSVC)

(V: Premature ventricular contraction

V couplet: Ventricular couplet
V short run: Short ventricular run (non-sustained ventricular tachycardia)
V long run: Long ventricular run (sustained ventricular tachycardia)
V bigeminy: Ventricular bigeminy
V trigeminy: Ventricular trigeminy)
(S: Premature supraventricular contraction
S couplet: Supraventricular couplet
S short run: Short supraventricular run (non-sustained SVT)
S long run: Long supraventricular run (sustained SVT)
S bigeminy: Supraventricular bigeminy
S trigeminy: Supraventricular trigeminy)

  • AF: Atrial flutter
  • Af: Atrial fibrillation
  • N: Normal beat
  • Vf: Ventricular flutter
  • L: Pause (cardiac pause / pause in heartbeat)
  • vf: Ventricular fibrillation
  • 0: Artifact waveform
  • BC: Bradycardi

Automated Arrhythmia Analysis

Leverage 10+ pre-set templates—atrial premature beats, ventricular premature beats, long intervals, atrial fibrillation, and more—plus user-defined patterns. The system classifies and flags pathologic waveforms to streamline review.

Supported Arrhythmia Events

  • V: Premature ventricular contraction (PVC)

(V: Premature ventricular contraction

V couplet: Ventricular couplet
V short run: Short ventricular run (non-sustained ventricular tachycardia)
V long run: Long ventricular run (sustained ventricular tachycardia)
V bigeminy: Ventricular bigeminy
V trigeminy: Ventricular trigeminy)

  • S: Premature supraventricular contraction (PSVC)

(V: Premature ventricular contraction

V couplet: Ventricular couplet
V short run: Short ventricular run (non-sustained ventricular tachycardia)
V long run: Long ventricular run (sustained ventricular tachycardia)
V bigeminy: Ventricular bigeminy
V trigeminy: Ventricular trigeminy)(S: Premature supraventricular contraction
S couplet: Supraventricular couplet
S short run: Short supraventricular run (non-sustained SVT)
S long run: Long supraventricular run (sustained SVT)
S bigeminy: Supraventricular bigeminy
S trigeminy: Supraventricular trigeminy)

  • AF: Atrial flutter
  • Af: Atrial fibrillation
  • N: Normal beat
  • Vf: Ventricular flutter
  • L: Pause (cardiac pause / pause in heartbeat)
  • vf: Ventricular fibrillation
  • 0: Artifact waveform
  • BC: Bradycardi

Atrial fibrillation analysis

Premature supraventricular contraction

Advanced Analytics, All in One Suite

Unlock deeper insight with built-in modules: QT dispersion (QTD), vectorcardiography (VCG), ventricular late potentials (VLP), and time vector cardiography (TVCG). These tools elevate reports from basic rhythm review to comprehensive cardiac assessment.

Bottle-sized portable oxygen concentrator next to a 1-liter water bottle, showing 1.8 kg weight.
Bottle-sized portable oxygen concentrator next to a 1-liter water bottle, showing 1.8 kg weight.

Advanced Analytics, All in One Suite

Unlock deeper insight with built-in modules: QT dispersion (QTD), vectorcardiography (VCG), ventricular late potentials (VLP), and time vector cardiography (TVCG). These tools elevate reports from basic rhythm review to comprehensive cardiac assessment.

Bottle-sized portable oxygen concentrator next to a 1-liter water bottle, showing 1.8 kg weight.
Bottle-sized portable oxygen concentrator next to a 1-liter water bottle, showing 1.8 kg weight.

Pacemaker-Compatible Analysis

Accurately recognizes and analyzes all common pacing modes, including AAI, VVI, DDD and more, with dedicated pacing templates such as dual chamber, atrial, ventricular, pseudofusion, and asynchronous. This ensures pacemaker signals are clearly identified and properly interpreted without compromising diagnostic accuracy.

Bottle-sized portable oxygen concentrator next to a 1-liter water bottle, showing 1.8 kg weight.
Bottle-sized portable oxygen concentrator next to a 1-liter water bottle, showing 1.8 kg weight.

Multi-Scale HRV Analysis

Provides heart rate variability (HRV) evaluation across 5-minute, 1-hour, and full-recording windows. These metrics reveal autonomic function and long-term trends, supporting risk assessment and follow-up care.

Multi-Scale HRV Analysis

Provides heart rate variability (HRV) evaluation across 5-minute, 1-hour, and full-recording windows. These metrics reveal autonomic function and long-term trends, supporting risk assessment and follow-up care.

ST-Segment analysis

Advanced ST-Segment & Ischemia Analysis

Abnormal ST changes are assessed both globally and at event level, combined with total ischemia load evaluation. This comprehensive view helps physicians accurately judge myocardial ischemia and guide clinical decisions.

Advanced ST-Segment & Ischemia Analysis

Abnormal ST changes are assessed both globally and at event level, combined with total ischemia load evaluation. This comprehensive view helps physicians accurately judge myocardial ischemia and guide clinical decisions.

ST-Segment analysis

HRT for Post-MI Risk Stratification

The Heart Rate Turbulence (HRT) module quantifies turbulence onset and slope after ventricular premature beats to assess autonomic function. Abnormal HRT is associated with higher mortality risk after myocardial infarction (MI), helping clinicians stratify risk and plan follow-up, not as a standalone diagnosis.

HRT for Post-MI Risk Stratification

The Heart Rate Turbulence (HRT) module quantifies turbulence onset and slope after ventricular premature beats to assess autonomic function. Abnormal HRT is associated with higher mortality risk after myocardial infarction (MI), helping clinicians stratify risk and plan follow-up, not as a standalone diagnosis.

For Clinics and Community Screening

Designed for clinical departments and scalable community

 screening—supporting patient-level diagnosis and population management with a unified workflow and standardized reports.

How to use the Holter Monitor

4 Steps to Complete Your ECG Test

Wellue patch recorder

1

Start recording an ECG/EKG

Please place the electrodes, then start to record an ECG/EKG for at least 5 minutes. 

Wellue AI-ECG pc software

2

Download PC software

Click the button below to download the software. The software currently supports Windows only

detect irregular heartbeat (arrhythmias) with Wellue 24-Hour ECG Recorder with AI analysis

3

Connect the device to the software

Connect the devive to your computer via the data cable, then click "Import Data" once the device is connected (make sure the device is disconnected from the app). 

download and share the ECG reports and waveforms

4

Print the ECG report

You can click “Print” to print a hard-copy report, or save the report as a PDF file.

What's Included

what's included in the mini portable oxygen concentrator package.
  • Holter monitor

  • Electrodes *10pcs

  • Leads (1 set)

  • USB 2.0 cable

  • PC software

  • Backpack

  • User manual

In Case You Need Extra Accessories

Frequently Asked Questions

Need Help? We've got you covered!

Does the software support iOS/macOS?

Sorry, not at this time—the analysis software supports Windows only.

Is the analysis software paid?

No. The software is free of charge.

What is the maximum monitoring duration?

Up to 24 hours of continuous 12-lead ECG recording.

What analyses are included?

Automated arrhythmia templates (10+), HRV (5-min/1-hr/whole), advanced ST-segment & ischemia load, T-Wave Alternans (TWA), Heart Rate Turbulence (HRT), and pacing analysis.

How do I obtain the report?

Install the Windows PC software (12 Channels ECG Holter System) in advance. After recording, connect the device to your computer via the included data/power cable to view the full ECG dataset and AI-assisted analysis. Clinicians can edit notes and print the report or save as PDF.

What does the final report include?

Full-disclosure ECG review, rhythm classifications, HRV metrics, ST/ischemia load, pacing findings, and clinician notes; you can print or save as PDF.

Does it work with pacemakers?

Yes. It provides pacemaker-compatible analysis (e.g., AAI/VVI/DDD and related pacing patterns) for accurate interpretation in paced patients.

Can I export ECG data to third-party analysis software?

Not supported. Data export is currently limited to our 12 Channels ECG Holter System for clinical review and report editing.

Technical Specifications

Physical & Tech Details


Dimension

75 x 101 x 283 mm (2.95" x 3.98" x 11.14")

Net Weight

3.97 lb (1.8 kg) with a single battery;

4.96 lb (2.25 kg) with double batteries.

Oxygen Flow

Flow settings 1, 2, 3, 4, 5

Oxygen Concentration

93%±3% at 1-3 settings;

≥60% at the setting of 4;

≥40% at the setting of 5

Maximum Oxygen Output

1000 ml/min

Flow Mode

Pulse Mode;

Active Mode

Technology

Pressure Swing Adsorption (PSA)

Sound

≤60 dB

Breathing Frequency

10 to 40 BPM

Environmental Ranges for Use

Temperature: 5 to 40˚C

Humidity: 10% - 80%, no condensing

Atmospheric Pressure: 61-101.3 kPa

Battery & Charging


Battery type

2 *AA battery

Battery Running Time

24~36 Hours

Warranty


Main Unit

1 Year

  • Physical & Tech Details
  • Battery
  • Warranty

Dimension

60 x 111 x 25 mm (2.4" x 4.4" x 1")

Net Weight

105g/3.7oz (excluding battery)

Number of Channels

12 channels

Sampling Rate

250Hz

Sampling Accuracy

24bit

Recording Time

24 hours

CMRR

≥60dB

Gain Accuracy

2mV ± 10%

Noise Level

≤ 50µV

Frequency Response

5Hz as benchmark, 0.05Hz~40Hz (± 3dB~-3dB)

Interfere Between Channels

≤ 0.2mV

Enduring Polarization Voltage

± 300mV

Scan Speed

25mm/s

Battery type

2 *AA battery

Battery Running Time

24~36 Hours

Main Unit

1 Year

Free Shipping

Free shipping. The referenced transit time is 2-6 business days for shipping in the USA. Note: Extra 2-4 business days may be needed for shipping internationally.

30-Day Money Back Guarantee

At any time within 30 days of receiving your order, you are not 100% satisfied, you may return it to us for a refund.
If you bought the product from www.getwellue.com, you can return it to us. Your payment card will be credited upon receipt of the returned merchandise. Any items damaged due to reasons not covered under warranty cannot be accepted back for refund under our 30 Day Money Back Guarantee.
If you are sure you want to return the goods, please contact us at first at support@getwellue.com. We provide 24/7 ticket and email support. Please contact us if you need assistance.

Disclaimer

The 12-Lead Holter Monitor is intended for recording and reviewing ambulatory ECG data. It does not replace professional medical judgment, diagnosis, or treatment. Data and reports should be interpreted by qualified healthcare professionals and used in conjunction with a complete clinical evaluation. The device is not intended for real-time emergency monitoring or life-support. If you experience chest pain, shortness of breath, syncope, or any acute symptoms, seek immediate medical attention or call emergency services. For questions about your health or ECG findings, consult your physician or another qualified healthcare provider.

Reviews, Q&A

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

You May Also Like