Yes, the Biocare iE6 6-Channel 12-Lead ECG Machine has pacemaker detection capability, ensuring accurate readings for patients with implanted devices.
6-Channel 12-Lead ECG/EKG Machine
with Intuitive Touchscreen Enhancing Big Diagnostic Efficiency at Your Fingertips
* Rx only, for use by doctors or trained healthcare professionals.
Digital Electrocardiograph (iE6)
Intuitive 6-Channel 12-Lead ECG Machine with Touchscreen Enhances Diagnostic Efficiency at Your Fingertips
* Rx only, for use by doctors or trained healthcare professionals.
6-Channel ECG Sheet
Record & print 6 channels of data at a time, more time saving
Adults & Pediatrics
Support ECG tests and analysis for adults & children
Intuitive User Interface
Fewer steps to set up an ECG test on the touchscreen
Integration of Patient Data
Seamless integration with the HIS through LAN and USB 2.0
Advisory ECG Diagnosis
Automatically interprets 12-lead ECG waveforms
6-Channel ECG Sheet
Record & print 6 channels of data at a time, more time saving
Adults & Pediatrics
Support ECG tests and analysis for adults & children
Intuitive Interface
Fewer steps to set up an ECG test on the touchscreen
Integration of Patient Data
Seamless integration with the HIS through LAN and USB 2.0
Advisory ECG Diagnosis
Automatically interprets 12-lead ECG waveforms
Intuitive User Interface, Fewer Steps to Set
30-300 Seconds Rhythm Time
Supports single rhythm and triple rhythms analysis from 30 to 300 seconds.
Pacemaker Detection
Guarantees accurate readings in patients with implanted devices.
Various Operation Modes
Various modes (auto, manual, rhythm) for flexible operation based on specific needs.
Filters for Noise Reduction
Complete digital filters and self-adapting filtering guarantee noise elimination without waveform distortion
Efficiency at Your Fingertips
Designed for one-touch operation, this ECG machine simplifies workflow and boosts cardiologist's diagnostic confidence.
12 Lead Simultaneous Acquisition
Simulataneously acquire 12 leads for comprehensive cardiac analysis.
Ideal for healthcare professionals who require accurate and detailed ECG monitoring for diagnostic and treatment purposes.
Also suitable for medical facilities, clinics, and hospitals seeking a reliable and user-friendly ECG machine for their patients.
Thermal Printer for Instant Printouts
Equipped with a built-in thermal printer, this ECG machine allows automatic printout upon arrhythmia recoginition during an examination.
112 mm-wide z-fold paper for printing meets clinical needs, ensuring optimal printing quality and ease of use.
Thermal Printer for Automatic Printouts
Equipped with a built-in thermal printer, this ECG machine allows automatic printout upon arrhythmia recognition during an examination.
112 mm-wide z-fold paper for printing meets clinical needs, ensuring optimal printing quality and ease of use.
Unparalleled Cardiac Analysis
Proved Biocare CardioPro™ ECG Analysis Program
Proven by official CSE database evaluation with high accuracy and reliability in measurement and interpretation.
QRS Detection
The sensitivity and specificity of QRS detection and analysis are up to 99%.
Especially for Pediatrics
Exclusive analysis module for children and pediatrics with 250Hz low-pass filter, meets the newest standard of AHA/ACC/HRS 2007.
Advisory ECG Analysis for Clinical Reference
It automatically interprets ECG waveforms (manual mode included) based on the Biocare CardioPro™ ECG Analysis Program.
Sensitive in S-T segment Diagnosis
0.01 Hz for high-pass filter of ECG signal contributes to undistorted ST segment measurement and analysis.
HRV Acquisition
Heart rate variability acquisition and review, providing valuable insights into heart health.
Fast Defibrillation Recovery
Less than 3 seconds. Defibrillation protected for reliable performance even during emergency situations.
Adivisory ECG Analysis for Clnical Reference
It automatically interprets ECG waveforms (manual mode included) based on the Biocare CardioPro™ ECG Analysis Program.
Proved Biocare CardioPro™ ECG Analysis Program
Proven by official CSE database evaluation with high accuracy and reliability in measurement and interpretation.
Proved Biocare CardioPro™ ECG Analysis Program
Proven by official CSE database evaluation with high accuracy and reliability in measurement and interpretation.
Sensitive in ST Segment Diagnosis
0.01 Hz for high-pass filter of ECG signal contributes to undistorted ST segment measurement and analysis.
QRS Detection
The sensitivity and specificity of QRS detection and analysis are up to 99%.
QRS Detection
The sensitivity and specificity of QRS detection and analysis are up to 99%.
HRV Acquisition
Heart rate variability acquisition and review, providing valuable insights into heart health.
Especially for Pediatrics
Exclusive analysis module for children and pediatrics with 250Hz low-pass filter, meets the newest standard of AHA/ACC/HRS 2007.
Especially for Pediatrics
Exclusive analysis module for children and pediatrics with 250Hz low-pass filter, meets the newest standard of AHA/ACC/HRS 2007.
Fast Defibrillation Recovery
Less than 3 seconds. Defibrillation protected for reliable performance even during emergency situations.
ECG Reports Print Preview
Previewing ECG reports before printing ensures accuracy and reduces the waste of resources.
Simple analysis report includes simple measurement data, median beat waveforms, analysis results, and rhythm waveforms.
Detailed measurement data such as S-T segment data is stated clearly, creating a complete picture of a patient's heart rhythm.
Real-time waveform freezing is available for in-depth analysis and review.
Interoperability with Hospital Information System
By connecting to the hospital information system via LAN and USB 2.0 flash drive, the ECG Management System (that supports HL7 integration) ensures seamless integration of patient data. This interoperability allows for comprehensive patient record management, enabling physicians to make informed decisions and provide better care.
Convenient Data Management
Store Up to 3,500 ECG Files
The machine is able to store 3,500 ECG files when the ECG acquisition time is 10 seconds.
Export Files in 5 Formats
Memory and data transfer in ECG, XML, JPEG, DICOM, PDF for compatibility with others.
3 Hours Continuous Operation
Rechargeable digital unit lasts for about 3 hours of continuous ECG work.
Multiple Ports to Connect
Independent Lead Wires
Unique ECG data acquisition module with independent lead wires, better in signal quality, faster in acquisition and less cost in maintenance.
Compact & Portable, Ready for Any Setting
Weighing only 2.5kg (5.5 lbs) and with a built-in handle, the Biocare iE6 ECG Machine is a portable device that can be easily transported between different healthcare settings, allowing for convenient use in clinics, hospitals, and even remote locations.
Compact & Portable, Ready for Any Setting
Weighing only 2.5kg (5.5 lbs) and with a built-in handle, the Biocare iE6 ECG Machine is a portable device that can be easily transported between different healthcare settings, allowing for convenient use in clinics, hospitals, and even remote locations.
Our Customers
What's in the Box
Main ECG Unit
Patient Lead Wire (1 set)
Limb Clamp Clip (1 set)
Chest Suction Ball (1 set)
ECG Snap-Clip Adapters (10 pieces)
Disaposable Electrodes (10 pieces)
Power Cables (US & EU Standard)
AC Power Adaptor
Equipotential Grounding Cable
Thermal Recording Grid Paper (z-fold paper)
User Manual
Qualified Certificate
Packing List
In Case You Need More
Specifications
- Physical Details
- Tech Spec
- Power Supply
- Input & Output
Device Dimensions
10.1'' x 11.4'' x 4.2''
(257 mm×291 mm×106 mm)
Weight
5.5 lb (2.5 kg)
Display
- Adults (older than 12 years old);
- Pediatrics (age: 29 days - 12 years old);
- Neonates (infants born less than 28 days)
- EMG filter: 25/35/75/100/150/250 Hz
- Baseline wander filter: 0.01/0.02/0.05/0.35/0.5/0.8 Hz
- AC filter: 50/60 Hz
- Single rhythm mode: 30-300 seconds
- Three rhythms mode: 30-100 seconds for each lead
- Standard leads: 3×4, 3×4+1R, 3×4+3R, 6×2, 6×2+1R, 1×12+1R;
- Nehb lead: 6×1, 3×2;
- ≥3500 ECG files (when the ECG acquisition time is 10 seconds ),
- support external SD card, USB 2.0 drive
Questions & Answers
Can this ECG machine be used with patients who have pacemakers?
Is there on-screen operation guide to check the ECG procedure?
Yes, tap the lead status on the top left corner of the display.
Is there a voice reminder for lead-off?
Yes. Alarm prompt for Lead-off detection, lead overflow, AC interference, baseline wander interference, EMG interference.
Is the Biocare iE6 CE and FDA certificated?
Yes. It is certificated by FDA (K141946), CE, NMPA.
Reviews, Q&A
Free Shipping
30-Day Money Back Guarantee
Maintenance Warranty
Regulatory & Compliance
The intended use of Biocare digital electrocardioggraph (Model: IE6) is to acquire ECG signals from adult and pediatric patients through body surface ECG electrodes. The product has received CE mark (EC CERTIFICATE LINK) and FDA approval (FDA CLEARANCE LINK). The electrocardiograph is only intended to be used in hospitals and healthcare facilities by doctors and trained healthcare professionals. The proposed device has analysis feature, however the ECG with measurements and interpretive statements is offered to clinician on an advisory basis only. Any non-clinical purposes will void any applicable product warranty. Please carefully read and understand all cautions, warnings and operational manuals prior to use.