Yes, the Biocare iE6 6-Channel 12-Lead ECG Machine has pacemaker detection capability, ensuring accurate readings for patients with implanted devices.


Digital Electrocardiograph
(iE 6)
Intuitive 6-Channel ECG Machine with Touchscreen Enhances Efficiency at Your Fingertips
* Rx only, for use by doctors or trained healthcare professionals.

Digital Electrocardiograph (iE 6)
Intuitive 6-Channel ECG Machine with Touchscreen Enhances Efficiency at Your Fingertips
* Rx only, for use by doctors or trained healthcare professionals.
6-Channel ECG Sheet
Record & print 6 channels of data at a time, more time saving
Authorized Guarantee
CE & FDA approved, no worry about its accuracy and safety
Adults & Pediatrics
Support ECG tests and analysis for adults & children
Intuitive User Interface
Fewer steps to set up an ECG test on the touchscreen
Integration of Patient Data
Seamless integration with the HIS through LAN and USB 2.0
Advisory ECG Diagnosis
Automatically interprets 12-lead ECG waveforms
Intuitive User Interface, Fewer Steps to Set


30-300 Seconds Rhythm Time
Support single rhythm and triple rhythms analysis from 30 to 300 seconds

Pacemaker Detection
Guarantees accurate readings in patients with implanted devices

Various Operation Modes
Various modes (auto, manual, rhythm) for flexible operation based on specific needs

Filters for Noise Reduction
Complete digital filters and self-adapting filtering guarantee noise elimination without waveform distortion
Efficiency at Your Fingertips
Designed for one-touch operation, this ECG machine simplifies workflow and boosts cardiologist's diagnostic confidence.





12 Lead Simultaneous Acquisition
Simulataneously acquire 12 leads for comprehensive cardiac analysis.
Ideal for healthcare professionals who require accurate and detailed ECG monitoring for diagnostic and treatment purposes.
Also suitable for medical facilities, clinics, and hospitals seeking a reliable and user-friendly ECG machine for their patients.
Thermal Printer for Instant Printouts
Equipped with a built-in thermal printer, this ECG machine allows automatic printout upon arrhythmia recoginition during an examination.
112 mm-wide z-fold paper for printing meets clinical needs, ensuring optimal printing quality and ease of use.


Thermal Printer for Automatic Printouts
Equipped with a built-in thermal printer, this ECG machine allows automatic printout upon arrhythmia recognition during an examination.
112 mm-wide z-fold paper for printing meets clinical needs, ensuring optimal printing quality and ease of use.
Unparalleled Cardiac Analysis
Proved Biocare CardioPro™ ECG Analysis Program
Proven by official CSE database evaluation with high accuracy and reliability in measurement and interpretation.

QRS Detection
The sensitivity and specificity of QRS detection and analysis are up to 99%.

Especially for Pediatrics
Exclusive analysis module for children and pediatrics with 250Hz low-pass filter, meets the newest standard of AHA/ACC/HRS 2007.


Advisory ECG Analysis for Clinical Reference
It automatically interprets ECG waveforms (manual mode included) based on the Biocare CardioPro™ ECG Analysis Program.

Sensitive in S-T segment Diagnosis
0.01 Hz for high-pass filter of ECG signal contributes to undistorted ST segment measurement and analysis.

HRV Acquisition
Heart rate variability acquisition and review, providing valuable insights into heart health.

Fast Defibrillation Recovery
Less than 3 seconds. Defibrillation protected for reliable performance even during emergency situations.

Adivisory ECG Analysis for Clnical Reference
It automatically interprets ECG waveforms (manual mode included) based on the Biocare CardioPro™ ECG Analysis Program.
Proved Biocare CardioPro™ ECG Analysis Program
Proven by official CSE database evaluation with high accuracy and reliability in measurement and interpretation.


Proved Biocare CardioPro™ ECG Analysis Program
Proven by official CSE database evaluation with high accuracy and reliability in measurement and interpretation.

Sensitive in ST Segment Diagnosis
0.01 Hz for high-pass filter of ECG signal contributes to undistorted ST segment measurement and analysis.

QRS Detection
The sensitivity and specificity of QRS detection and analysis are up to 99%.
QRS Detection
The sensitivity and specificity of QRS detection and analysis are up to 99%.


HRV Acquisition
Heart rate variability acquisition and review, providing valuable insights into heart health.

Especially for Pediatrics
Exclusive analysis module for children and pediatrics with 250Hz low-pass filter, meets the newest standard of AHA/ACC/HRS 2007.
Especially for Pediatrics
Exclusive analysis module for children and pediatrics with 250Hz low-pass filter, meets the newest standard of AHA/ACC/HRS 2007.


Fast Defibrillation Recovery
Less than 3 seconds. Defibrillation protected for reliable performance even during emergency situations.
ECG Reports Print Preview
Previewing ECG reports before printing ensures accuracy and reduces the waste of resources.

Simple analysis report includes simple measurement data, median beat waveforms, analysis results, and rhythm waveforms.

Detailed measurement data such as S-T segment data is stated clearly, creating a complete picture of a patient's heart rhythm.

Real-time waveform freezing is available for in-depth analysis and review.
Interoperability with Hospital Information System
By connecting to the hospital information system via LAN and USB 2.0 flash drive, the ECG Management System (that supports HL7 integration) ensures seamless integration of patient data. This interoperability allows for comprehensive patient record management, enabling physicians to make informed decisions and provide better care.

Convenient Data Management
Store Up to 3,500 ECG Files
The machine is able to store 3,500 ECG files when the ECG acquisition time is 10 seconds.
Export Files in 5 Formats
Memory and data transfer in ECG, XML, JPEG, DICOM, PDF for compatibility with others.
3 Hours Continuous Operation
Rechargeable digital unit lasts for about 3 hours of continuous ECG work.
Multiple Ports to Connect


Independent Lead Wires
Unique ECG data acquisition module with independent lead wires, better in signal quality, faster in acquisition and less cost in maintenance.

Compact & Portable, Ready for Any Setting

Weighing only 2.5kg (5.5 lbs) and with a built-in handle, the Biocare iE6 ECG Machine is a portable device that can be easily transported between different healthcare settings, allowing for convenient use in clinics, hospitals, and even remote locations.
Compact & Portable, Ready for Any Setting
Weighing only 2.5kg (5.5 lbs) and with a built-in handle, the Biocare iE6 ECG Machine is a portable device that can be easily transported between different healthcare settings, allowing for convenient use in clinics, hospitals, and even remote locations.
Choose the Right ECG for Your Practice
MOST INTUITIVE
MOST ADVANCED
MOST EFFICIENT
Most Intuitive
Most Advanced
Most Efficient
Channels
Record 6 channels of data at a time
Record 12 channels at a time, fastest speed
Record 3 channels at a time
Lead Mode
Standard 12 leads; Cabrera
Standard 12 leads; Cabrera; Nehb, VCG
Standard 12 leads
Display
8 Inches, 15° angled display for easy readability
9 Inches, 15° angled display for easy readability
5 Inches
Screen
Touchable, time-saving operation
Touchable, time-saving operation
Non-touchable
Battery
Rechargeable, 3-hour continuous work
Rechargeable, 3-hour continuous work
Rechargeable, 3-hour continuous work
Full Keyboard
Yes, for quick input of patient data
Yes, for quick input of patient data
No
Local Storage
3,500 files
3,500 files
1,500 files
Thermal Paper
Z-fold paper: 112*140mm
Z-fold paper: 210*140mm
Rolled paper: 20*80mm
Weight
2.5KG
3.4KG
1.3KG
Channels
Record 6 channels of data at a time
Record 12 channels at a time, fastest speed
Record 3 channels at a time
Lead Mode
Standard 12 leads; Cabrera
Standard 12 leads; Cabrera; Nehb, VCG
Standard 12 leads
Display
8 Inches, 15° angled display for easy readability
9 Inches, 15° angled display for easy readability
5 Inches
Screen
Touchable, time-saving operation
Touchable, time-saving operation
Non-touchable
Battery
Rechargeable, 3-hour continuous work
Rechargeable, 3-hour continuous work
Rechargeable, 3-hour continuous work
Full Keyboard
Yes, for quick input of patient data
Yes, for quick input of patient data
No
Local Storage
3,500 files
3,500 files
1,500 files
Thermal Paper
Z-fold paper: 112mm*140mm
Z-fold paper: 210mm*140mm
Rolled paper: 20mm*80mm
Weight
2.5KG
3.4KG
1.3KG
Our Customers
Accessories in the Package

Chest Suction Ball ×6

Limb Clamp Clip ×4

Disposable Electrodes ×10

Lead Wire Adapters (from Banana plug to snap or clip) ×10

ECG Acquisition Box with Lead Wire

Z-fold Thermal Paper (160 Pieces: 112mm × 140mm)

Power Cord ×2 (US & EU Standard) & AC Power Adapter

Equipotential Grounding Cable
What's in the Box

Main ECG Unit
Patient Lead Wire (1 set)
Limb Clamp Clip (1 set)
Chest Suction Ball (1 set)
ECG Snap-Clip Adapters (10 pieces)
Disaposable Electrodes (10 pieces)
Power Cables (US & EU Standard)
AC Power Adaptor
Equipotential Grounding Cable
Thermal Recording Grid Paper (z-fold paper)
User Manual
Qualified Certificate
Packing List
In Case You Need More
For Extra Electrodes
For Extra ECG Paper
For Extra Lead Wires
Questions & Answers
Can this ECG machine be used with patients who have pacemakers?
Is there on-screen operation guide to check the ECG procedure?
Yes, tap the lead status on the top left corner of the display.

Is there a voice reminder for lead-off?
Yes. Alarm prompt for Lead-off detection, lead overflow, AC interference, baseline wander interference, EMG interference.
Is the Biocare iE6 CE and FDA certificated?
Yes. It is certificated by FDA (K141946), CE, NMPA.


Reviews, Q&A
Tech Specs
PRODUCT
Digital Electrocardiograph (Model: iE6)
WEIGHT (MAIN UNIT)
5.5lbs / 2.5kg
DEVICE DIMENSIONS
10.1'' x 11.4'' x 4.2''
(257 mm×291 mm×106 mm)
SCREEN
8.0'' TFT LCD full-view display
AC POWER SUPPLY
100V-240V, 50Hz/60Hz, 80VA
DC POWER SUPPLY
Rechargeable Lithium battery(14.8V/ 2200mAh)for 3-hour continuous operation
LEAD MODE
Standard 12 leads, Cabrera
PATIENT TYPE
Adults (older than 12 years old); Pediatrics (age: 29 days - 12 years old);
neonates (infants born less than 28 days)
ACQUISITION MODE
Simultaneous 12-lead Acquisition
RHYTHM TIME
30s~300s waveforms acquisition for rhythm analysis
COMPATIBLE COMPUTER SYSTEM
Windows XP, Win7, Win8, Vista in
32/64 bit
SAMPLING RATE
8,000 samples/second/channel
RECORD FORMAT
12-lead: 3×4,3×4+1R,3×4+3R,6×2,6×2+1R,1×12+1R
Nehb-lead: 6×1,3×2
RECORDER
Thermal Dot Matrix Word Printing System
RECORDING PAPER
Z- fold paper, 112 mm×140 mm
PRINTING SPEED
(5, 6.25, 10, 12.5, 25, 50) mm/s ±5%
DATA STORAGE
≥3500 records (10-second acquisition)
USB Port
USB 2.0 drive
CERTIFICATION
NMPA, FDA, CE
pulse oximeter
Maintenance Warranty
Our company guarantees the new instrument on the material and technological qualification for this product within 18 months and the accessories within 6 months since the purchasing day, while consumables are not included in the guarantee. This warranty is inapplicable to the products undergoing any modifications, disassembles, refittings or self-repairings without the permission of our company. We're not responsible of the products damaged by accidents such as fire, thunder and lightning, flood and other disasters, intentional damage, improper installation and improper usage.
30-Day Money Back Guarantee
During the first 30 days after receiving your order, if you are not 100% satisfied with our service, feel free to return your device to us for a refund. Only the purchase on getwellue.com can return to us. Your payment card will be credited upon your receipt of the returned merchandise. Any item damaged due to reasons that are not included in the warranty cannot be qualified for a refund. If you are certain to return your orders, please contact us first at support@getwellue.com. We provide 24/7 ticket inquiry and email support. Thank you for choosing Wellue Health!
Shipping
Free shipping. The referenced transit time is 2-6 business days for shipping in the USA. Note: Extra 2-4 business days may be needed for shipping internationally.
Regulatory & Compliance
THE INTENDED USE OF BIOCARE DIGITAL ELECTROCARDIOGRAPH (MODEL: IE6) IS TO ACQUIRE ECG SIGNALS FROM ADULT AND PEDIATRIC PATIENTS THROUGH BODY SURFACE ECG ELECTRODES. the product HAS RECEIVED CE MARK (EC CERTIFICATE LINK) AND FDA APPROVAL (FDA CLEARANCE LINK). The electrocardiograph is only intended to be used in hospitals or healthcare facilities by doctors and trained healthcare professionals. The proposed device has analysis feature, however the ECG with measurements and interpretive statements is offered to clinician on an advisory basis only. ANY NON-CLINICAL PURPOSES WILL VOID ANY APPLICABLE PRODUCT WARRANTY. PLEASE CAREFULLY READ AND UNDERSTAND ALL CAUTIONS, WARNINGS AND OPERATIONAL MANUALS PRIOR TO USE.