It supports up to 360 hours of historical data storage (based on system settings and use conditions).

FDA-CLEARED

2-YEAR WARRANTY

30 DAYS RETURN

FREE SHIPPING
8-Inch Touchscreen Patient Monitor with Printer
Transport to bedside: multi-parameter monitoring with deep insights
Terms & Conditions

8-Inch Touchscreen Patient Monitor with Printer
Transport to bedside: multi-parameter monitoring with deep insights
Terms & Conditions
FDA-CLEARED
2-YEAR WARRANTY
30 DAYS RETURN
Multi-Parameter Monitoring Made Clear and Efficient
The 8-Inch Touchscreen Patient Monitor with Printer delivers comprehensive multi-parameter monitoring, including ECG, PR, SpO₂, NIBP, RESP, and TEMP, with optional EtCO₂. It supports advanced clinical analysis and calculations to help clinicians interpret trends faster and document with confidence. Built for adult, pediatric, and neonatal care. It can also be configured with optional central monitoring system (CMS) to enable remote viewing of patient parameters.

Multi-Parameter Monitoring Made Clear and Efficient
The 8-Inch Touchscreen Patient Monitor with Printer delivers comprehensive multi-parameter monitoring, including ECG, PR, SpO₂, NIBP, RESP, and TEMP, with optional EtCO₂. It supports advanced clinical analysis and calculations to help clinicians interpret trends faster and document with confidence. Built for adult, pediatric, and neonatal care. It can also be configured with optional central monitoring system (CMS) to enable remote viewing of patient parameters.

Who Is It For

For Ward Care

For Ambulance (On-Transport)

For Community Care

For Home Health Care

Touchscreen Control
Touchscreen Control

Handle & Portable Design

Flexible Display Views for Every Clinical Scenario
- 1 ECG
- 2 ECG
- 3 ECG
- 7 ECG
- 9 Channel Wave
- big ECG
- Huge Digit
- Mini Trend
- oxyCRG









Advanced Clinical Analysis & Calculations



ST-segment analysis
By default, the ST segment is displayed.
Pacemaker monitoring
Supports pacemaker detection during ECG monitoring.
5 Calculations
Built-in calculations for hemodynamics, drug dose, oxygenation, renal function, and ventilation.
Advanced Clinical Analysis & Calculations
Clear Alerts When It Matters Most

Clear Alerts When It Matters Most
Set adjustable alarm limits to match patient condition and department needs, with clear on-screen alerts and sound notifications. The monitor can store up to 1,000 alarm eventswith corresponding waveforms for efficient review and documentation.
Unique Nasal Tube Respiration Monitoring

Patient with upper airway obstruction

Newborns

Burn Patients
Unique Nasal Tube Respiration Monitoring

Patient with upper airway obstruction

Patient with upper airway obstruction

Newborns

Burn Patients
Built-in Thermal Printer

USB Data Export for Simple Review
Export recorded data to a standard USB flash drive (included). Insert it into a computer to view numeric values in an Excel-compatible spreadsheet for quick review and documentation.

Optional End-Tidal CO2 Monitoring

Optional End-Tidal CO2 Monitoring
End-tidal CO₂ monitoring provides real-time insight into a patient’s ventilation and perfusion status, helping clinicians assess respiratory function, detect changes early, and guide timely interventions.
Optional Central Monitoring System
Enable centralized, real-time oversight by connecting bedside monitors to an optional Central Monitoring System (CMS) via wired networking. Designed for efficient multi-bed surveillance and alarm management, the CMS supports flexible layouts, streamlined patient admission, and robust review and printing tools for clinical workflows.
Automatic, real-time bedside monitoring
Alarm list printing
Sequential trend review
Locate function from trend diagram to ECG waveform
Single or dual-screen display
Simple, intelligent patient admission
compatible with HL7-based hospital systems
Connect up to 64 monitors, supports EtCO₂ and IBP

Optional Central Monitoring System
Enable centralized, real-time oversight by connecting bedside monitors to an optional Central Monitoring System (CMS) via wired networking. Designed for efficient multi-bed surveillance and alarm management, the CMS supports flexible layouts, streamlined patient admission, and robust review and printing tools for clinical workflows.
Automatic, real-time bedside monitoring
Alarm list printing
Sequential trend review
Locate function from trend diagram to ECG waveform
Single or dual-screen display
Simple, intelligent patient admission
compatible with HL7-based hospital systems
Connect up to 64 monitors, supports EtCO₂ and IBP

Who Is It For


What's In the Box
8.4" Touchscreen Patient Monitor with Built-in Printer
Power cord x2
ECG cable (5-lead)
ECG pad x10
NIBP cable
TEMP probe x2
Adult sized NIBP cuff
Adult sized SpO2 probe
Thermal printer paper x1
USB flash drive
User manual
In Case You Need Extra Accessories
Accessories for Pediatric Patients

What's In the Box
8.4" Touchscreen Patient Monitor with Built-in Printer
Power cord x2
ECG cable (5-lead)
ECG pad x10
NIBP cable
TEMP probe x2
Adult-size NIBP cuff
Adult-size SpO2 probe
Thermal printer paper x1
Nasal sampling cannula X 4
USB flash drive
User manual
Frequently Asked Questions
How much history can it store?
How many alarm events can be stored?
The monitor can store up to 1,000 alarm events, each with the corresponding waveform (all alarm events).
How many NIBP measurements can be saved?
It can store up to 1,500 NIBP measurement records for quick lookup and documentation.
Does it support EMR integration?
This patient monitor supports electronic medical record (EMR) use cases (capabilities depend on your workflow/software integration).
Can I export data?
Yes. It supports USB data export for convenient data transfer.
How many arrhythmia events can be stored?
The monitor can store up to 500 arrhythmia events, each with the corresponding waveform for review.
Can I adjust the touchscreen sensitivity?
Yes. If you’d like to improve touch accuracy, you can recalibrate the touchscreen using Touch Adjust.
How to recalibrate:
1. Tap Menu
2. Tap Tools
3. Select Touch Adjust
4. Tap the 5 on-screen points in sequence
5. Wait for the monitor to restart automatically to complete calibration
Can't find an answer to your question?
Email us at support@getwellue.com
Specifications
- TECH DETAILS
- BATTERY
- WARRANTY
Model
Visualbeat
Weight
0.63 oz / 18g
Device Dimensions
3.94'' x 0.91'' x 0.33''
Heart Rate Range
30 - 250 BPM
Degree of Dust & Water Resistance
IP22
Wireless
Bluetooth 5.0, compatible with 4.0
Built-In Memory
Up to 10 sessions/30 hours in total;
Up to 24 hours for each session
Battery Type
Rechargeable lithium-polymer, 48 hours for typical use
Battery Running Time
48 hours for typical use
Battery Charging Time
2-3 hours
Main unit
1 Year
Specifications
- TECH DETAILS
- ECG
- SPO2
- PI
- NIBP
- RESP
- TEMP
- THERMAL PRINTER
- SIDESTREAM ETCO2 (OPTIONAL)
Size
9.5'' (L) x 6.4'' (W) x 8.3'' (H)
Weight
4.96 lb / 2.25 kg
Display
8.4" color TFT LCD touchscreen
Power
Input: AC 100 V~240V, 50/60Hz
Battery type: lithium-ion battery
Battery capacity: 2600mAh
Data Storage
Trend data: 480hrs
Arrhythmia events: 500 ARR events
NIBP review: 1500 groups
Alarm Events: 1,000 events with waveforms
Network Connection
Wired LAN, RJ45 port
Working Mode
Monitoring mode, Demo mode, Standby mode
Warranty
2 year (service life: 5 years)
Demo Password
1112
Lead section
I, II, III, aVR, aVL, aVF, V1-V6
Gain selection
×1/4, ×1/2, ×1, ×2, ×4 and automatic
Sweep speed
3.125, 6.25, 12.5, 25, 50mm/s
Heart rate range
15~350bpm
Calibration
±1mv
Accuracy
±1bpm or ±1% (select the bigger data)
Defib-proof & ESU-proof
Yes
Pacemaker monitoring
Yes
Display type
Waveform, Data
Measurement range
0~100%
Accuracy
±3% (between 70%~100%)
SpO2 resolution
1%
Pulse rate range
25~250bpm
Accuracy
±1bpm or ±2% (select the bigger data)
Measurement range
30 ~ 250 bpm
Measurement precision
±1bpm or ±2 %, whichever is greater
Resolution
1bpm
Method
Oscillometry
Measurement parameter
Systolic, Diastolic, Mean
Measurement method
Manual, Auto, Continuous
Measuring range
SYS: 30-270mmHg
DIA: 10-200mmHg
MAP: 20-220mmHg
Resolution
1mmHg
Accuracy
Max average error: ±5mmHg
Max standard deviation
8mmHg
Measurement interval in auto mode
2/3/4/5/6/7/8/9/10/15/20/25/30/35/40/45/50/55 minutes and 1/1.5/2/2.5/3/3.5/4/4.5/5/5.5/6/6.5/717.5/8 hours
Measurement time in continuous mode
5 minutes
Method
Thoracic impedance
Measurement precision
±1rpm or ±5 %, whichever is greater
Resolution
Resolution
Lead option
lead I, lead II and lead III; default lead II
Channel
dual-channel
Measurement and alarm range
77.0°F to 113.0°F
Resolution
0.1 °F
Accuracy
±0.3 °F
Recording speed
25 mm/s; 50 mm/s
Paper size
50mm x 20m
Waveform width
48mm
Total waveform number
3
Type of EtCO2 Sensor
SideStream
Measurement range
0%~19.7%, 0~150mmHg, 0~20kpa
Accuracy
0~40mmHg ±2mmHg
41~70mmHg ±5% of reading
71~100mmHg ±8% of reading
101~150mmHg ±10% of reading