Diagnosis and location for myocardial infarction, especially for posterior and inferior myocardial infarction.
Increasing sensitivity and odds of detecting ST-segment elevation in acute myocardial infarction.
* Rx only, for use by doctors or trained healthcare professionals.
* Rx only, for use by doctors or trained healthcare professionals.
12-Channel ECG Sheet
View & print 12 channels of data at a time, highly efficient
Authorized Accuracy
CE & FDA approved, guaranteed accuracy and safety
Adults & Pediatrics
Support ECG tests and analysis for both adults & children
Advisory ECG Diagnosis
12-Lead ECG with interpretation for precise diagnosis
VCG Acquisition
Vectorcardiogram (VCG) acquisition for more advanced diagnosis
9-Inch Touchscreen
High-resolution color touchscreen interface for easy navigation
Easy Data Management
Multiple ports and formats for wireless ECG data transmission
Compact & Portable
With a built-in handle, easy to carry between healthcare settings
12-Channel ECG Sheet
View & print 12 channels of data at a time, highly efficient
Authorized Accuracy
CE & FDA approved, guaranteed accuracy and safety
Adults & Pediatrics
Support ECG tests and analysis for both adults & children
Advisory ECG Diagnosis
12-Lead ECG with interpretation for precise diagnosis
VCG Acquisition
Vectorcardiogram (VCG) acquisition for more advanced diagnosis
9-Inch Touchscreen
High-resolution color touchscreen interface for easy navigation
Easy Data Management
Multiple ports and formats for wireless ECG data transmission
Compact & Portable
With a built-in handle, easy to carry between healthcare settings
Most Advanced
Most Intuitive
Most Efficient
Most Portable
Compared with iE300 and iE6 ECG Machine, the iE12A ECG has more advantages
Vectorcardiogram (VCG) acquisition & review for diagnosing and locating specific types of myocardial infarction
Quicker tracing and processing of ECG signals in 12 channels, more time-saving
Handling a larger volume of ECG tests efficiently, easier to diagnose certain conditions, and detect arrhythmias
Equipped with easy-to-use touchscreen, simple clear interface, full keyboard, built-in handle
Vectorcardiogram (VCG) acquisition & review for diagnosing and locating specific types of myocardial infarction
Handling a larger volume of ECG tests efficiently, easier to diagnose certain conditions, arrhythmia detection
Quicker recording and processing of ECG signals in 12 channels, more time-saving
Equipped with easy-to-use touchscreen, simple clear interface, full keyboard, built-in handle
With its user-friendly design, the ECG machine ensures easy operation and navigation. Medical professionals can effortlessly access and interpret the ECG parameters, streamlining the diagnostic process and improving efficiency.
The ECG machine can process 12 leads of ECG signals at the same time, providing a comprehensive view of the heart's electrical activity. This allows for a more accurate diagnosis and assessment of cardiac conditions.
Specific age and gender differential validity in Biocare's CardioPro™ ECG analysis program maximizes the accuracy of the ECG interpretation. The analysis program has been proven by the official CSE (Common Standards for Quantitative Electrocardiography) database evaluation with high accuracy and reliability in measurement and interpretation.
Vectorcardiogram (VCG), a kind of cardiogram for observing and recording the 3D electrical activities of human hearts, is commonly used for the diagnosis and location of myocardial infarction, especially for posterior and inferior myocardial infarction. It can accurately record every moment of vector value, direction and process of change. When the ECG diagnosis is uncertain, a VCG test may help.
Myocardial Infarction
Diagnosis and location for myocardial infarction, especially for posterior and inferior myocardial infarction.
Increasing sensitivity and odds of detecting ST-segment elevation in acute myocardial infarction.
Conduction Block
Determination of bundle branch conduction block and branch conduction block.
Pre-excitation Syndrome
Location of pre-excitation syndrome bypass.
Atrial and Ventricular Hypertrophy
Diagnosis for atrial and ventricular hypertrophy, especially for right ventricular hypertrophy.
Myocardial Infarction
Diagnosis and location for myocardial infarction, especially for posterior and inferior myocardial infarction.
Conduction Block
Determination of bundle branch conduction block and branch conduction block.
Pre-excitation Syndrome
Location of pre-excitation syndrome bypass.
Atrial and Ventricular Hypertrophy
Diagnosis for atrial and ventricular hypertrophy, especially for right ventricular hypertrophy.
It can identify pacemaker types and working status through ECG analysis and provide automatic measurement of QRS amplitude.
Tap Rhythm Mode, it will begin HRV waveforms acquisition and you can review waveforms in 300 seconds.
Up to 300 seconds of R-R analysis in 1 or 3 rhythm leads makes it easier to locate arrhythmias. R-R trend and histogram are also available for clinical reference.
Auto-trigger printing when an arrhythmia is detected during the examination. Extended additional printout to review a significant arrhythmia event after the auto ECG operation.
Barcode scanner (connected with USB port) to quickly input patient's ID
On-screen guide to check for loose leads and alarming
Preview the report before printing
Adjustable printing speed from 5mm/s to 50mm/s. Various formats for printing: 3×4, 3×4+R, 3×4+3R, 6×2, 6×2+R, 6×2+3R, 12, 12+R, 12+3R. Waveforms are displayed in a 1:1 ratio with grid lines that align with doctors' diagnostic practices
Choose economic recording mode to save on paper costs. All waveforms and analysis results are printed on a large thermal paper (210 mm×140 mm), facilitating easy comparison and enabling doctors to quickly conduct and assess ECG tests.
ECG (Electrocardiogram)
VCG (Vectorcardiogram)
Interoperability can be gained with the help of ECG Management Systems by HL7 protocol. Physicians can also securely manage patient records within the hospital network.
The machine is able to store 3,500 ECG files when the ECG acquisition time is 10 seconds.
Memory and data transfer in ECG, XML, JPEG, DICOM, PDF for compatibility with others.
Rechargeable digital unit lasts for about 3 hours of continuous ECG work.
With its compact and portable design, the ECG machine offers the flexibility to be used in various healthcare settings. It can be easily transported between different departments or even for on-site patient monitoring, ensuring continuous cardiac assessment.
With its compact and portable design, the ECG machine offers the flexibility to be used in various healthcare settings. It can be easily transported between different departments or even for on-site patient monitoring, ensuring continuous cardiac assessment.
Included in the package, we provide everything you need to support the operation of the whole unit as below.
Chest Suction Ball ×6
Limb Clamp Clip ×4
Disposable Electrodes ×10
Lead Wire Adapters (from Banana plug to snap or clip) ×10
ECG Acquisition Box with Lead Wire
Z-fold Thermal Paper (160 Pieces: 112mm × 140mm)
Power Cord ×2 (US & EU Standard) & AC Power Adapter
Equipotential Grounding Cable
Need Help? We've got you covered!
Reviews, Q&A
Tech Specs
PRODUCT
Digital Electrocardiograph (Model: iE12A)
WEIGHT (MAIN UNIT)
7.5lbs / 3.4kg
DEVICE DIMENSIONS
13.6" × 10.2" × 5.1"
(345 mm × 260 mm × 128.5 mm)
SCREEN
8.9'' TFT LCD full-view display
AC POWER SUPPLY
100V-240V, 50Hz/60Hz, 80VA
DC POWER SUPPLY
Rechargeable built-in lithium battery (14.8V/ 4400mAh), support 3-hour operation
CERTIFICATION
NMPA, FDA, CE
COMPATIBLE COMPUTER SYSTEM
Windows XP, Win7, Win8, Vista in
32/64 bit
LEAD MODE
Standard 12 leads, Nehb, Cabrera, Frank
PATIENT TYPE
Adults (older than 12 years old); Pediatrics (age: 29 days - 12 years old);
neonates (infants born less than 28 days)
ACQUISITION MODE
Simultaneous 12-lead Acquisition
RHYTHM TIME
30s~300s waveforms acquisition for rhythm analysis
SAMPLING RATE
8,000 samples/second/channel
DATA FORMAT
ECG, XML, JPEG, DICOM, PDF
MEASUREMENT PARAMETERS
Standard leads: HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage and RV5+SV1 voltage;
Nehb lead: HR, PR interval, P duration, T duration, QRS duration, QT/QTC interval, P/QRS/T axis, P amplitude
RECORD FORMAT
Standard leads: 3×4, 3×4+1R, 3×4+3R, 6×2, 6×2+1R, 6×2+3R, 12×1;
Nehb lead: 6×1, 3×2;
VCG: 6×1+3, 3×2+3, 3×2+3+1R, 3×2+3+3R, Frank
RECORDER
Thermal Dot Matrix Word Printing System
RECORDER MODE
Economic, Auto, Manual, Upload, Cycle, Trigger
RECORDING PAPER
Z- fold paper, 210 mm×140 mm -140P
PRINTING SPEED
(5, 6.25, 10, 12.5, 25, 50) mm/s ±5%
DATA STORAGE
≥3500 records (10-second acquisition), support SD card, U disk
USB PORT
USB 2.0 drive ONLY, support external scanner
pulse oximeter
What's in the box?
Main ECG Unit
Patient Lead Wire (1 set)
Limb Clamp Clip (1 set)
Chest Suction Ball (1 set)
ECG Snap-Clip Adapters (10 pieces)
Disaposable Electrodes (10 pieces)
Power Cables (US & EU Standard)
AC Power Adapter
Equipotential Grounding Cable
Thermal Recording Grid Paper (z-fold paper)
User Manual
Qualified Certificate
Packing List
Warranty Card
Maintenance Warranty
Our company guarantees the new instrument on the material and technological qualification for this product within 18 months and the accessories within 6 months since the purchasing day, while consumables are not included in the guarantee. This warranty is inapplicable to the products undergoing any modifications, disassembles, refittings or self-repairings without the permission of our company. We're not responsible of the products damaged by accidents such as fire, thunder and lightning, flood and other disasters, intentional damage, improper installation and improper usage.
30-Day Money Back Guarantee
During the first 30 days after receiving your order, if you are not 100% satisfied with our service, feel free to return your device to us for a refund. Only the purchase on getwellue.com can return to us. Your payment card will be credited upon your receipt of the returned merchandise. Any item damaged due to reasons that are not included in the warranty cannot be qualified for a refund. If you are certain to return your orders, please contact us first at support@getwellue.com. We provide 24/7 ticket inquiry and email support. Thank you for choosing Wellue Health!
Shipping
Free shipping. In general, the referenced transit time is 2-4 business days for shipping in the USA. Note: Extra 2-4 business days will be needed for shipping internationally.
Regulatory & Compliance
THE INTENDED USE OF BIOCARE DIGITAL ELECTROCARDIOGRAPH (MODEL: IE12A) IS TO ACQUIRE ECG SIGNALS FROM ADULT AND PEDIATRIC PATIENTS THROUGH BODY SURFACE ECG ELECTRODES. THE PRODUCT HAS RECEIVED CE MARK (EC CERTIFICATE LINK) AND FDA APPROVAL (FDA CLEARANCE LINK). THE ELECTROCARDIOGRAPH IS ONLY INTENDED TO BE USED IN HOSPITALS OR HEALTHCARE FACILITIES BY DOCTORS AND TRAINED HEALTHCARE PROFESSIONALS. THE PROPOSED DEVICE HAS ANALYSIS FEATURE, HOWEVER THE ECG WITH MEASUREMENTS AND INTERPRETIVE STATEMENTS IS OFFERED TO CLINICIAN ON AN ADVISORY BASIS ONLY. ANY NON-CLINICAL PURPOSES WILL VOID ANY APPLICABLE PRODUCT WARRANTY. PLEASE CAREFULLY READ AND UNDERSTAND ALL CAUTIONS, WARNINGS AND OPERATIONAL MANUALS PRIOR TO USE.