- Diagnosis and location for myocardial infarction, especially for posterior and inferior myocardial infarction.
- Increasing sensitivity and odds of detecting ST-segment elevation in acute myocardial infarction


Digital Electrocardiograph (iE 12A)
Digital 12-Channel High End ECG Machine with Printer
Get A Complete & Quick View of 12-Channel ECG Waveforms in Great Efficiency
* Rx only, for use by doctors or trained healthcare professionals.

Digital Electrocardiograph (iE 12A)
Digital 12-Channel High End ECG Machine with Printer
Get a complete & quick view of 12-channel ECG waveforms with great efficiency
* Rx only, for use by doctors or trained healthcare professionals.
12 Channel ECG Sheet
View and print in 12 channels, highly effcient
Authorized Accuracy
FDA & CE approved.
9-Inch Touch Screen
High resolution color touchscreen with handwriting
Adults & Pediatrics
Support ECG tests for both adults & children
Auto-analysed Result
12-lead ECG with interpretation for advisory diagnosis.
VCG Acquisition
Provide advanced analysis of Vectorcardiography
Compact & Portable
Built-in handle, easy to carry
Multiple file options
Multiple ports and formats for ECG data transmission
12-Lead Simultaneous Acquisition
The ECG machine is able to simultaneously process 12 leads of ECG signals with automatically interpretation. Its user-friendly design ensures easy operation and freedom of built-in ECG parameters measurement and interpretation.


Print 12-Channel ECG Waveforms in Seconds
Adjustable printing speed from 5mm/s to 50mm/s. Various formats for printing: 3×4, 3×4+R, 3×4+3R, 6×2, 6×2+R, 6×2+3R, 12, 12+R, 12+3R. All waveforms and analysis results are printed on large size of thermal paper (210 mm×140 mm), making it easy for doctors to take instant ECG tests and compare.
Built-in Handle for Remote ECG Tests
Biocare iE12A portable EKG machine weighs about 3.4kg (7.5lbs). With its built-in handle, the unit is easy to carry to anywhere the patient need the most. Perfect choice for ambulance or such emergency medical services.

High-Resolution Touchscreen with Handwriting Function
The 9-inch TFT-LCD display with a 15-degree angle is clear to read every detail of 12-lead ECG signals. Its touchable screen makes the operating system faster, saving time for cardiologists, physicians, or EMS staff.
Shortcut Keys Make Efficient Clinical Operations
The unique ECG data acquisition box with standard character keyboard streamlines the whole workflow.
- Waterproof and alphanumeric keyboard with backlight silicone shortcut keys for easy operation.
- Icon buttons on the screen for intuitive operation.


Advanced Features Make An intelligent ECG Machine
3 Ways of file storage: Local memory, SD card, USB flash disk
- Massive local storage for more than 3500 files
- Multiple peripheral ports for data transmation: USB, LAN, SD card slot
Multiple ECG file formats: XML, DICOM, JPEG, PDF and more
2 Ways of power source: Built-in rechargeable lithium battery for up to 3 hours of continuous work and AC power.
Get Patient Electrocardiogram in 3 Steps

1
Barcode scanner to quickly input patient's ID

2
On-screen guide to check for loose leads and alarming

3
Preview the report before printing
VCG Acquisition For More Advanced Diagnosis
Vectorcardiogram (VCG), a kind of cardiogram for observing and recording the 3D electrical activities of human hearts, is commonly used for diagnosis and location for myocardial infarction, especially for posterior and inferior myocardial infarction. It can accurately record every moment of vector value, direction and process of changing. When the ECG diagnosis is uncertain, a VCG test may help.

Myocardial infarction
- Determination of bundle branch conductive block and branch conduction block
Pre-excitation syndrome
- Location of pre-excitation syndrome bypass
Atrial and ventricular hypertophy
- Diagnosis for atrial and ventricular hypertophy, especially for right ventricular hypertrophy
12-Lead ECG with Authorized Interpretation
Specific age and gender differential validity in Biocare's CardioPro™ ECG analysis program maximize the accuracy of the ECG interpretation. The analysis program has been proven by official CSE (Common Standards for Quantitative Electrocardiography) database evaluation with high accuracy and reliability in measurement and interpretation.

Advisory Analysis for adults & pediatrics
- 0.01 Hz for high-pass filter, more sensitive in weaker ECG signal detection, contributes to undistorted ST-segment measurement and analysis.
- Exclusive analysis module for pediatrics with 250Hz low-pass filter meets the latest standard of AHA (American Hospital Association) /ACC ( American College of Cardiology) /HRS 2007 (Heart Rhythm Society).
Simple analysis report includes simple measurement data, median beat waveforms, analysis results, and rhythm waveforms.
Detailed Measurement Data for clinical Reference

Print Reports in ECG & VCG Formats
Waveforms are in ratio of 1:1 with grid lines in the background that matches the diagnosis practice of doctors.


Easy ECG Management System in Hospitals
Interoperability can be gained with the help of ECG Management Systems. Physicians can also securely manage patient records within the hospital network.

* Support ECG management system by HL7 protocol
Easily Find out the Data That You Need
Search faster by patient information, disease, date, ID and medical record number.

Choose the right ECG for your practice
HIGH-END
MOST COST-EFFECTIVE
MOST PORTABLE
High-end
Most Cost-Effective
Most Portable
Channels
12 Channels
3 Channels
12 Channels
Lead Mode
Standard 12 leads; Cabrera; Nehb, VCG
Standard 12 leads
Standard 12 leads; 6 leads
Display
9 Inches
5 Inches
4.46 Inches
Screen
Touchable
Non-touchable
Touchable
Battery
Rechargeable, 3-hour continuous work
Rechargeable, 3-hour continuous work
Rechargeable, 24-hour continuous work
Local Storage
3,500 files
1,500 files
10,000+ files
Thermal Paper
Z-fold paper: 210mm*140mm
Rolled paper: 20mm*80mm
Need an external printer
Weight
3.4KG
1.3KG
250g
Accessories You Have in the Box
Included in the package, we provide everything you need to support the operation of the whole unit:
one set of limb electrodes (4 pcs)
one set of chest electrodes (6 pcs)
one set of ECG snap-clip adapters (10 pcs)
one pack of disaposable electrodes (10 pcs)
one set of lead wires
one piece of equipotential cable
one power cable, AC power adaptor
z-fold paper

Lead Wires

Limb Clips x4

Equipotential Cable

Chest Electrodes x6

Disposable Electrodes x10

ECG Snap-clip Adapters x10

AC Power Adaptor

Z-fold paper
In Case You Need More
If you have any questions. We will answer them for you
- Quality Management Systems: EN ISO13485
- Electrical Safety: IEC 60601-1
- EMC: EN/IEC 60601-1-2
- Particular Safety: IEC 60601-2-25
- Biological compatibility: ISO10993
- Software: EN/IEC 62304
Reviews, Q&A
Tech Specs
WEIGHT (MAIN UNIT)
7.5lbs / 3.4kg
DEVICE DIMENSIONS
13.6" × 10.2" × 5.1"
345 mm × 260 mm × 128.5 mm
SCREEN
8.9'' TFT LCD full-view display
FREQUENCY RESPONSE
0.05 Hz~250 Hz
COMMON MODE REJECTION
>110dB (AC filter on)
>100dB (AC filter off)
DC POWER SUPPLY
Rechargeable built-in lithium battery (14.8V/ 4400mAh), support 3-hour operation
INPUT
Touch screen, Standard full keyboard, Shortcut key, Support external scanner
DATA STORAGE
≥3500 ECG files (when the ECG acquisition time is 10 seconds ), support external SD card、U disk
Data Format
Data format ECG, XML, JPEG, DICOM, PDF
LEAD Mode
Standard 12-lead, Nehb, Cabrera, Frank
RHYTHM TIME
Record for a long term (30 s~300 s) and rhythm analysis
PATIENT TYPE
Adults & Pediatrics
ACQUISITION MODE
Simultaneous 12-lead Acquisition
MEASUREMENT PARAMETERS
Standard leads: HR, PR interval, QRS duration, QT/QTC interval, P/QRS/T axis, RV5/SV1 voltage and RV5+SV1 voltage;
Nehb lead: HR, PR interval, P duration, T duration, QRS duration, QT/QTC interval, P/QRS/T axis, P amplitude
INPUT CIR CURRENT
≤0.1 μA
PATIENT LEAK CURRENT
<10 μA
TIME CONSTANT
≥3.2 s
FILTERS
AC, low-pass and high-pass filters
RECORDER TECHNOLOGY
Thermal Dot Matrix Word Printing System
RECORDER Mode
Economic, Auto, Manual, Upload, Cycle, Trigger
RECORDING PAPER
Z- fold paper : 210 mm×140 mm-140 p
PRINTING SPEED
5 / 6.25 / 10 / 12.5 / 25 / 50mm/s
RECORD FORMAT
Standard leads: 3×4, 3×4+1R, 3×4+3R, 6×2, 6×2+1R, 6×2+3R, 12×1;
Nehb lead: 6×1, 3×2;
VCG: 6×1+3, 3×2+3, 3×2+3+1R, 3×2+3+3R, Frank
ALARM PROMP
Lead-off detection, lead overflow, AC interference, baseline wander interference, EMG interference
COMPATIBLE PC SYSTEM
Windows XP, Win7, Win8, Vista in
32/64 bit
PRODUCT
Digital Electrocardiograph (Model: iE12A)
pulse oximeter
What's in the box?
Main ECG Unit
Lead Wires (1 set)
Limb Electrodes (1 set)
Chest Electrodes (1 set)
ECG Snap-Clip Adapters (10 pieces)
Disaposable Electrodes (10 pieces)
Power Cable
AC Power Adaptor
Equipotential Cable
Z-fold Paper
User Manual
Qualified Certificate
Packing List
Warranty Card
Maintenance Warranty
Our company guarantees the new instrument on the material and technological qualification for this product within 18 months and the accessories within 6 months since the purchasing day, while consumables are not included in the guarantee. This warranty is inapplicable to the products undergoing any modifications, disassembles, refittings or self-repairings without the permission of our company. We're not responsible of the products damaged by accidents such as fire, thunder and lightning, flood and other disasters, intentional damage, improper installation and improper usage.
30-Day Money Back Guarantee
During the first 30 days after receiving your order, if you are not 100% satisfied with our service, feel free to return your device to us for a refund. Only the purchase on getwellue.com can return to us. Your payment card will be credited upon your receipt of the returned merchandise. Any item damaged due to reasons that are not included in the warranty cannot be qualified for a refund. If you are certain to return your orders, please contact us first at support@getwellue.com. We provide 24/7 ticket inquiry and email support. Thank you for choosing Wellue Health!
Shipping
Free shipping. In general, the referenced transit time is 2-8 business days for shipping in the USA. Extra 2-4 business days may be needed for shipping internationally.
Regulatory & Compliance
THE INTENDED USE OF BIOCARE DIGITAL ELECTROCARDIOGRAPH (MODEL: IE12A) IS TO ACQUIRE ECG SIGNALS FROM ADULT AND PEDIATRIC PATIENTS THROUGH BODY SURFACE ECG ELECTRODES. THE PRODUCT HAS RECEIVED CE MARK (EC CERTIFICATE LINK) AND FDA APPROVAL (FDA CLEARANCE LINK). THE ELECTROCARDIOGRAPH IS ONLY INTENDED TO BE USED IN HOSPITALS OR HEALTHCARE FACILITIES BY DOCTORS AND TRAINED HEALTHCARE PROFESSIONALS. THE PROPOSED DEVICE HAS ANALYSIS FEATURE, HOWEVER THE ECG WITH MEASUREMENTS AND INTERPRETIVE STATEMENTS IS OFFERED TO CLINICIAN ON AN ADVISORY BASIS ONLY. ANY NON-CLINICAL PURPOSES WILL VOID ANY APPLICABLE PRODUCT WARRANTY. PLEASE CAREFULLY READ AND UNDERSTAND ALL CAUTIONS, WARNINGS AND OPERATIONAL MANUALS PRIOR TO USE.